Fire alarm and sprinkler manufacturers discuss when to maintenance.

When danger strikes, people need to be alert and ready to act. Fires are just one of these dangers. Fortunately, there is technology to both alert and actively fight fires: fire alarms and sprinklers. To keep these working properly in case danger arises, maintenance is necessary. In this manufacturer roundtable, Healthcare Facilities Today speaks with leading fire alarms and sprinklers manufacturers about when healthcare facility managers should maintenance their alarms and sprinklers.

When should sprinklers and alarm systems receive maintenance?

“Systems should receive ITM in accordance with the codes that apply to the type of systems and types of facilities in which they are installed.  NFPA 25 is just one of the standards that might apply. Additionally, whenever an issue presents itself – such as a dripping wet system pipe or a broken dry system auxiliary drain – the system should be fixed immediately.”

—George McHugh, vice president, AGF Manufacturing, Inc. 

“Fire alarm systems must be inspected, tested and maintained in accordance with NFPA 72 National Fire Alarm and Signaling Code. Similar to NFPA 25, NFPA 72 provides various frequencies for the inspection, testing and maintenance of fire alarm system components. NFPA 25 and NFPA 72 address common components such as fire sprinkler control valves, fire sprinkler waterflow indicators and the vast variety of fire alarm initiating devices like manual pull stations and smoke detectors. However, the frequency and methods for inspecting, testing and maintaining these components might differ between the standards. The key, especially in a healthcare environment, is to have a very robust and accurate inspection, test and maintenance program for all types of life safety systems.”

—Larry Rietz, vice president and global service line leader for fire detection and alarm, Jensen Hughes 

“Sprinkler systems should be inspected, tested and maintained in accordance with NFPA 25 Standard for the Inspection, Testing and Maintenance of Water-Based Fire Protection Systems. NFPA 25 requires quarterly, semi-annual, and annual inspection, testing and maintenance activities. The better a system is maintained, the more reliable it will be. Proper inspection, testing and maintenance of fire sprinkler systems is critical since the systems remain dormant for long periods of time but must be relied upon in the event of a fire.”

—Donald Hopkins, Jr., vice president of process improvement, Jensen Hughes 

Jeff Wardon, Jr. is the assistant editor for the facilities market. 

The post "When to Perform Maintenance on Fire Alarms and Sprinklers" appeared first on Healthcare Facilities Today

0 Comments

Submit a Comment

How to properly assess structural wind damage

Prompt site assessment of wind damage from major storms such as hurricanes and tornadoes is a crucial step in determining...

Keeping outdoor workers safe in the summer

As the weather gets hotter and summer approaches, there are many maintenance workers who need to spend their days in the...

2023 Commercial Building Trends Include AI, Sustainability, and Predictive Maintenance

  In the aftermath of the COVID-19 pandemic, the commercial real estate and building management sectors have had the...

Preparing for Safe Electrical Disaster Recovery During Hurricane Season Using NFPA 70B

Hurricane season is officially upon us. Although the period can often begin earlier and run later, June 1 through November...

What’s Ahead for this Hurricane Season?

June marks the official start of hurricane season, which runs through Nov. 30. But how many of these potentially dangerous...