As buildings age, their structural conditions can deteriorate, causing damage and safety concerns. In order to mitigate this, it’s important to engage in the regular inspection and condition assessment of buildings for diagnosis.

One common form of structural deterioration is referred to as building movement and can surface in varying ways, including uneven floor slabs, cracks in walls, uneven ceiling panels, excessively compressed or extended joints, racked doors, water infiltration, and in extreme cases shifting or leaning columns or walls. Of course, when deformations continue untreated, the distress worsens, and the safety of the building and occupants is compromised.

Typically, building movement can be categorized in three primary ways: foundation or deep movement, slab-on-ground movement, and structural deficiencies.

What to Consider

Excessive movement affects occupant comfort, perception of safety, building serviceability, structural durability, and actual structural safety. As an example, the movement of slab-on-ground can result in the creation of trip hazards or sloped slab that exceeds ADA requirements or local accessibility standards, while structural safety concerns arise from unstable racked structures that can collapse.

Environmental factors also come into play. If the area is known for bad soil, poor site drainage, or large trees near the exterior perimeter of the building can exacerbate movement causing seasonal fluctuations of movement during the rainy season or during extended droughts.

Identifying problems and addressing them sooner mitigates both risk and cost, often making the extent of the repair much less.

With that in mind, how can property owners tackle issues preemptively?

There are some early diagnostic questions to consider:

  • Is the distress localized to one area or global?
  • What type of distress are they noticing?
  • What part of the building is experiencing the movement?
  • Are there any uneven slabs?
  • Are there any openings such as doors or windows no longer operating?
  • Has there been a recent change in use of the building or recent construction in or around the building?

Holistic Approach

It is significant to note that some level of building movement is acceptable and even expected. Depending on the site-specific soils, building materials, and location, there are varying degrees of expectations, uneven surfaces, and deflections. For example, building code allows for a limited amount of deflection that differs for various framing elements over a given length or height, and the slab-on-ground has an allowable tilt or curvature that is acceptable by code.

Building movement requires an engineering investigation to identify the root causes of the movement and to provide recommendations that address both the immediate concern and the long-term building performance. To address and mitigate ongoing building movement, it is often crucial that repairs be performed in tandem with one another in order to maintain the building. For instance, to properly address slab-on-ground-related distress, it is important to mitigate sources of soil moisture in conjunction with repairing the slab-on-ground while at the same time implementing repairs to the finishes that can accommodate some future differential movement.

At Walter P Moore, our team incorporates a holistic approach, combining the immediate needs with the long-term building performance. Walter P Moore’s expertise and technical knowledge combined with a focus on understanding our client’s needs allows us to provide repair recommendations and designs that are both practical and efficient.

About the Authors
Dan Barbuto, PE, is a Senior Project Manager for Walter P Moore’s Diagnostics Group, based in Houston. Abhishek Aggarwal, PE, is a Project Manager for Walter P Moore’s Diagnostics Group, balled in Dallas.

The post "Building movement: When is it a problem?" appeared first on Building Design & Construction

0 Comments

Submit a Comment

Groundbreaking School Security Standard Protects Students During Active Shootings

In the wake of the tragic rise in active shooter incidents at schools, the National Glass Association (NGA) took swift...

Upping the IAQ in your building

Allergens and dust are found in the air throughout the summer, so IAQ remains a priority year-round. Maintenance managers...

Businesses Bet Big on Data Analytics and Integrated Worktech

In today’s hybrid work landscape, organizations are striving to strike the perfect balance between boosting operational...

Initiative seeks to close emergency response gaps

Asleep in bed, the sound of sirens outside your condo awakens you in the middle of the morning. You hear no alarm and no...

Gen Z Can Fill the Workforce Gap

We may have done a disservice to the Gen Z group of young people. Facility management professionals often label them as...